Accidental machine starting can cause injury or death to personnel working on the machine. To avoid accidental machine starting, turn the battery disconnect switch to the OFF position and remove the key. If the machine is not equipped with a battery disconnect switch, disconnect the battery cables from the battery and tape the battery clamps. Place a do not operate tag at the battery disconnect switch location to inform personnel that the machine is being worked on. |
Note: Put identification marks on all wires for installation purposes.
- Turn the battery disconnect switch to the OFF position.
- Open the left door.
Show/hide table
Illustration 1 g00985719 - Remove bolts (1) and remove panel (2).
Show/hide table
Illustration 2 g00985720 - Remove bolt (7) in order to disconnect bracket (6). Slide back boot (3). Disconnect battery cables (4). Disconnect harness assembly (5).
Show/hide table
Illustration 3 g00985721 - Remove bolts (8) and remove electric starting motor (9).
![]() |
Accidental machine starting can cause injury or death to personnel working on the machine. To avoid accidental machine starting, turn the battery disconnect switch to the OFF position and remove the key. If the machine is not equipped with a battery disconnect switch, disconnect the battery cables from the battery and tape the battery clamps. Place a do not operate tag at the battery disconnect switch location to inform personnel that the machine is being worked on. |
- Position electric starting motor (9) and install bolts (8).
Show/hide table
Illustration 5 g00985720 - Connect harness assembly (5). Connect battery cables (4). Slide forward boot (3). Position bracket (6) and install bolt (7).
Show/hide table
Illustration 6 g00985719 - Position panel (2) and install bolts (1).
- Close the left door.
- Turn the battery disconnect switch to the ON position.
![]() | |
Illustration 4 | g00985721 |