854G and 854K Wheel Dozers and 992G, 992K and 994F Wheel Loaders VIMSTM MID 049 - CID 0364 - FMI 04 Caterpillar


MID 049 - CID 0364 - FMI 04
`
MID 049 CID 0364 FMI 04

Conditions Which Generate This Code:



Illustration 1g01078152
Schematic of the pressure sensor (lift cylinder, head end)

This diagnostic code is associated with the head end lift cylinder pressure sensor). The FMI 04 means that the ECM has determined that the voltage of the circuit for the sensor is below normal.

The pressure sensors are PWM sensors. The PWM signal is dependent on the input pressure and will vary between 200 Hz and 1600 Hz.

The possible causes of this diagnostic code are listed below:

  • The signal circuit for the sensor is shorted to ground.

  • The sensor has failed.

  • The ECM has failed. This is unlikely.

Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear the diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 0364 FMI 04 is active before performing this procedure.

Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.

Test Step 1. CHECK THE SENSOR

  1. Turn the disconnect switch and the key start switch to the ON position.

  2. Ensure that the diagnostic code is active.

  3. Observe the status of the diagnostic code. Disconnect the sensor from the machine harness.

Expected Result:

The CID 0364 FMI 04 remains active. The FMI has not changed and the "04" is still active.

Results:

  • OK - The diagnostic code remains active. The sensor is correct. Proceed to Test Step 2.

  • NOT OK - The diagnostic code is no longer active. The sensor has failed.

    Repair: Replace the sensor.

    STOP

Test Step 2. CHECK THE WIRING HARNESS OF THE SENSOR FOR A SHORT TO GROUND.

  1. Turn the key start switch and the disconnect switch to the OFF position.

  2. Disconnect the machine harness from the sensor.

  3. Disconnect the machine harness connector(s) from the ECM.

  4. At the machine harness connector for the ECM, measure the resistance from the signal contact J1-11 (wire C529-GY(Grey)) of the machine harness to all possible sources of ground. Measure the resistance to all contacts of the machine harness connectors for the ECM.

Expected Result:

Each resistance measurement is greater than 5000 ohms.

Results:

  • OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.

  • NOT OK - One or more resistance measurements is not correct. There is a short in the machine harness.

    Repair: The short is between signal contact J1-11 (wire C529-GY(Grey)) and the circuit with the low resistance measurement. Repair the machine harness or replace the machine harness.

    STOP

Test Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.

  1. Inspect the contacts of the harness connectors and clean the contacts.

  2. Reconnect all harness connectors.

  3. Turn the disconnect switch and the key start switch to the ON position.

  4. Operate the machine.

  5. Check the status of the CID 0364 FMI 04.

Expected Result:

The CID 0364 FMI 04 is active.

Results:

  • YES - The CID 0364 FMI 04 is active. The diagnostic code has not been corrected. The ECM may have failed.

    Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and Adjusting, "Module - Replace".

    STOP

  • NO - The CID 0364 FMI 04 is not active. The diagnostic code does not exist at this time.

    Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.

    STOP

Information System:

TH580B Telehandler Hydraulic System Location of Hydraulic Components
854G and 854K Wheel Dozers and 992G, 992K and 994F Wheel Loaders VIMSTM MID 049 - CID 0364 - FMI 03
966G II and 972G II Wheel Loaders Fuses - Replace - Machines that are Equipped with Electrohydraulic Controls and Conventional Steering
2004/07/05 A New Quick Coupler Improves Operator Visibility {6129}
2004/06/14 A New Cab Improves Operator Visibility {7301}
C13, C15, and C18 Tier 4 Final Engines Exhaust Manifold
THP10 Series II and THP24S Series II Access Platform for Series B Telehandlers Work Tool Troubleshooting
Removal and Installation Procedure for the Cab Air Filter (Pressurized Assembly){7342}
Inspection and Maintenance Procedure For the Dual Stage Precleaner{1055}
THP10 Series II and THP24S Series II Access Platform for Series B Telehandlers Hydraulic System
824H Wheel Dozer, 825H Soil Compactor and 826H Landfill Compactor Machine Systems Gear Pump (Pilot, Brake) - Remove
988H Wheel Loader Power Train Transmission Hydraulic Control Operation
854G and 854K Wheel Dozers and 992G, 992K and 994F Wheel Loaders VIMSTM MID 049 - CID 0809 - FMI 02
854G and 854K Wheel Dozers and 992G, 992K and 994F Wheel Loaders VIMSTM MID 049 - CID 0809 - FMI 12
854G and 854K Wheel Dozers and 992G, 992K and 994F Wheel Loaders VIMSTM MID 049 - CID 0810 - FMI 02
854G and 854K Wheel Dozers and 992G, 992K and 994F Wheel Loaders VIMSTM MID 049 - CID 0810 - FMI 12
988H Wheel Loader Electrohydraulic System Relief Valve (Pressure Relief for the Tilt Cylinder Line) - Test and Adjust
Fabricated Tool for Alternate Method of Tightening Fan Drive Belts{1357, 1397}
THP10 Series II and THP24S Series II Access Platform for Series B Telehandlers Specifications
THP10 Series II and THP24S Series II Access Platform for Series B Telehandlers Plate Locations and Film Locations
THP10 Series II and THP24S Series II Access Platform for Series B Telehandlers Daily Inspection
AD45B Underground Articulated Truck C18 Engine Supplement Engine Oil Cooler - Install
AD30 Underground Articulated Truck Transmission and Output Transfer Gears - Remove
973C Track-Type Loader Engine Supplement Engine - Remove