992K Wheel Loader Electrohydraulic System MID 082 - CID 0463 - FMI 06 Caterpillar


MID 082 - CID 0463 - FMI 06
`
MID 082 CID 0463 FMI 06

Conditions Which Generate This Code:



Illustration 1g01971721
Schematic for the Tilt Dual Relief Solenoid

This diagnostic code is associated with the Tilt Dual Relief Solenoid. The FMI 06 means that the ECM has determined that there is a short to ground in the solenoid circuit.

The possible causes for this diagnostic code are listed below:

  • The internal windings for the solenoid have low impedance.

  • The internal windings for the solenoid are shorted.

  • The signal circuit from the ECM to the solenoid is shorted to ground.

System Response:

The machine response is listed:

Since hydraulic flow to the cylinder is supplied by two control valves, the dump function is possible at a reduced rate.

Note: The following test procedure may create other diagnostic codes. Clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 0463 FMI 06 is active before performing this procedure.

Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.

Test Step 1. CHECK THE SOLENOID

  1. Turn the disconnect switch and the key start switch to the ON position.

    Note: Do not start the engine.

  2. Observe the status of the diagnostic code.

  3. Disconnect the solenoid with the active diagnostic code from the machine harness.

Expected Result:

The CID 0463 FMI 06 changes to CID 0463 FMI 05 when the solenoid is disconnected.

Results:

  • YES - The CID 0463 FMI 06 changes to CID 0463 FMI 05 when the solenoid is disconnected. The circuit is correct.

    Repair: The solenoid has failed. Repeat this test "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid.

    STOP

  • NO - The CID 0463 FMI 06 remains active. Proceed to Test Step 2.

Test Step 2. CHECK THE ENERGIZER CIRCUIT OF THE SOLENOID FOR A SHORT TO GROUND

  1. Turn the key start switch and the disconnect switch to the OFF position.

  2. The solenoid remains disconnected from the machine harness.

  3. Disconnect the machine harness connector(s) from the ECM.

  4. At the machine harness connector, measure the resistance from the signal contact J1-68 (wire K833-PK(Pink)) to all contacts that are used in the machine harness connectors for the ECM.

Expected Result:

Each resistance measurement is greater than 5000 ohms.

Results:

  • OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.

  • NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J1-68 (wire K833-PK(Pink)) and the circuit with the low resistance measurement.

    Repair: Repair the machine harness or replace the machine harness.

    STOP

Test Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS

  1. Inspect the harness connectors and clean the contacts of the harness connectors.

  2. Reconnect all harness connectors.

  3. Turn the disconnect switch and the key start switch to the ON position.

  4. Operate the machine.

  5. Check the status of the CID 0463 FMI 06.

Expected Result:

The CID 0463 FMI 06 is active.

Results:

  • YES - The CID 0463 FMI 06 is active. The diagnostic code has not been corrected. The ECM may have failed.

    Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, the ECM may have failed. Prior to replacing an ECM, always contact your dealership's Technical Communicator for possible consultation with AVSpare. This consultation may greatly reduce repair time. If the ECM requires replacement, refer to the Testing and Adjusting, "Electronic Control Module (ECM) - Replace" Story in this manual.

    STOP

  • NO - The CID 0463 FMI 06 is not active. The diagnostic code does not exist at this time.

    Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.

    STOP

Information System:

854G and 854K Wheel Dozers and 992G, 992K and 994F Wheel Loaders VIMS<SUP>TM MID 049 - CID 0890 - FMI 09
992K Wheel Loader Electrohydraulic System MID 082 - CID 0463 - FMI 05
992K Wheel Loader Electrohydraulic System MID 082 - CID 0463 - FMI 03
2009/11/12 Protective Covers For the Equalizer Bar Are Now Used On the D11T {7206}
988H Wheel Loader Electrohydraulic System Main Control Valve
992K Wheel Loader Electrohydraulic System MID 082 - CID 0361 - FMI 11
992K Wheel Loader Electrohydraulic System MID 082 - CID 0360 - FMI 11
C4.4 Industrial Engine Engine Oil Level - Check
3500 Engines Flywheel Housing
854G and 854K Wheel Dozers and 992G, 992K and 994F Wheel Loaders VIMSTM MID 049 - CID 0600 - FMI 06
854G and 854K Wheel Dozers and 992G, 992K and 994F Wheel Loaders VIMSTM MID 049 - CID 0600 - FMI 06
854G and 854K Wheel Dozers and 992G, 992K and 994F Wheel Loaders VIMSTM MID 049 - CID 0600 - FMI 04
992K Wheel Loader Electrohydraulic System MID 082 - CID 0463 - FMI 11
3500 Engines Housing (Front)
992K Wheel Loader Electrohydraulic System MID 082 - CID 2360 - FMI 04
992K Wheel Loader Electrohydraulic System MID 082 - CID 0590 - FMI 14
992K Wheel Loader Electrohydraulic System MID 082 - CID 1571 - FMI 11
C13, C15, and C18 Tier 4 Interim Engines ARD Failed to Ignite
AD30 Underground Articulated Truck Lifting and Tying Down the Machine
2009/10/16 Correction to Systems Operation Testing and Adjusting , "Pressure Reducing Valve (Pilot Oil) - Test and Adjust" {5117}
2009/09/28 Replacement Of The Gasket For The Rear Transmission Cover {3030, 7555}
953D, 963D and 973D Track-Type Loaders Monitoring System Electrical Connector - Inspect
2009/09/21 A Guard For the Pivot Shaft Seal Is Now Used On the D11T {4151}
2009/10/29 Improved Gaskets for the Oil Filter Base Are Now Used on Certain Engines {1306, 1308, 7555}