D7 Track-Type Tractors Information Display Pop-Up Messages - Monitoring System Action Lamps and Warning Categories Caterpillar


Pop-Up Messages - Monitoring System Action Lamps and Warning Categories
`
1.1. Pop-Up Warning Message Banners with a Service Fault Code
2.2. Warning Level 1 (Gray banner)
3.2. Warning Level 2 - (Amber banner)
4.2. Warning Level 3 - (Red banner): Level 3

Pop-Up Warning Message Banners with a Service Fault Code



Illustration 1g06600322
Gauges Page
(1) Warning Indicator Alert Reminder Lamp

Alert Reminder Lamp - This icon is designed to alert the operator to an event issue. The icon will flash three times to get the attention of the operator. The Cat monitoring system provides three warning categories. The first category requires only operator awareness. The second warning category requires an operator response. The third warning category requires immediate shutdown of the machine.

If the monitoring system detects an abnormal operating condition, the operator will be notified. The action alarm will appear on the indication display when a warning is active. The action lamp will flash red for warning level notifications.

The signal is received via the CAN data link from the engine ECM. The sequence for the warning levels is listed below:

  • Level 1 = no action lamp, no alarm

  • Level 2 = Amber flashing action lamp (1 second ON, 1 second OFF)

  • Red flashing action lamp (1 second ON, 1 second OFF), pulsing horn (1 second ON, 1 second OFF)

Note: If communication with the CAN data link is lost to the display module for 4 seconds or more, the indicator will turn Amber.

Note: Certain conditions will allow the machine to be operated in the limp home mode.

Table 1 indicates the status of the alarm for each warning level.

If the monitoring system detects an abnormal operating condition, the operator will be notified.

Note: For more information on Diagnostics, to the "Service Menu" section of this manual.

Table 1
Warning Operation 
Warning Level  Warning Indications  Action by the operator is required (1)  Possible Result (if no action is taken by the operator) 
Warning Indicators for the Subsystem Warning Lamp  Sounding of the Action Alarm 
ON  Flashes 3x before becoming a Solid Gray  OFF  No immediate action is required. The system needs attention soon  No harmful, damaging effects result 
ON  Flashes 3x before becoming a Solid Yellow  OFF  Change machine operation or perform maintenance to the system  The system components are damaged 
ON  Flashing Red  Pulse OFF and ON  Immediately perform a safe engine shutdown  The operator is injured or the components are damaged 
(1) Recommended action to be taken by the machine operator in response to the different warning levels:

Warning Level 1 (Gray banner)

This warning level will cause the involved system alert indicator to illuminate. A level 1 warning will indicate that the operator should be aware of a condition of the machine systems.



Illustration 2g06600325
Performance Page with Gauges
(1) Warning Indicator Alert Reminder Lamp
(2) Warning Banner
(3) Fault Code
(4) Warning Icon
(5) Fault Code Description
(6) Fault Code Condition
(7) Event Page Button

Warning Level 1 does not affect the operation of the machine or alert the operator that a warning has occurred. Warning Level 1 is recorded and may be viewed from the Diagnostics menu of the display or with Cat® Electronic Technician (ET) .

Note: Level 1 Events and Diagnostics will pop up and will snooze.

The Alert Reminder Lamp (1) will flash 3 times to alert the operator before becoming stationary.

  1. Press the Alert Reminder Lamp (1) to enlarge the Warning Banner (2).

  2. Press the Event Page Button (7) to page through the list of warnings.

Note: If multiple warnings are active simultaneously, the Warning Banner (2) will automatically cycle through the warnings.

Warning Level 2 - (Amber banner)

This warning level will indicate that the operation of the machine should be changed or maintenance should be performed. Possible damage to components on the machine may occur.



Illustration 3g06600330
Performance Page with Gauges
(1) Alert Reminder Lamp (Yellow)
(2) Warning Banner
(3) Fault Code
(4) Warning Icon
(5) Fault Code Description
(6) Fault Code Condition
(7) Event Page Button
(8) Event Page Counter

Warning Level 2 requires changing the operation of the machine or performing a maintenance procedure. Failure to correct the problem that caused this warning may damage the involved components or the involved system of the machine.

A Level 2 Warning Pop-Up Message Banner supersedes any active Level 1 Warning (Gray) Pop-Up Message.

Note: Level 2 Events and Diagnostics can be snoozed for 3600 seconds.

The Alert Reminder Lamp (1) will flash 3 times to alert the operator before becoming stationary.

  1. Press the Alert Reminder Lamp (1) to enlarge the Warning Banner (2).

    If there is more than one Event Page, the Event Page Counter (8) shows the operator that there is more than one message with that warning level.

  2. Press the Event Page Button (7) to page through the list of warnings.

Note: If multiple warnings are active simultaneously, the Warning Banner (2) will automatically cycle through the warnings.

Warning Level 3 - (Red banner): Level 3

This warning level will indicate that the machine needs to have an immediate, safe emergency shutdown. Possible injury to the operator or severe damage to components may occur. When a level 3 warning is active, the action alarm will sound a pulsing tone. The action alarm will sound these tones to alert the machine operator that immediate action is required. If two warnings of a different level are active at the same time, the highest level warning will be displayed. If a warning occurs, the message will override any item displayed in the banner area of the Graphical Display.



Illustration 4g06600334
Performance Page with Gauges
(2) Warning Banner
(3) Fault Code
(4) Warning Icon
(5) Fault Code Description
(6) Fault Code Condition

Level 3 Warnings are the highest priority. A Level 3 Warning Pop-Up message banner always supersedes an active Level 2 Warning (Amber) or active Level 1 Warning (Gray).

Warning Level 3 requires an immediate safe shutdown of the machine to avoid damage to the machine or injury to personnel around the machine. The problem that caused the event must be corrected before machine operation can resume.

A Level 3 Warning Pop-Up Message Banner supersedes any active Level 1 Warning (Gray) Pop-Up Message or any active Level 2 Warning (Amber) Pop-Up Message.

Note: Level 3 Events and Diagnostics can be reduced or snoozed. The operator should investigate the cause of the Level 3 message as soon as possible.

Note: If the monitoring system detects an abnormal operating condition, the operator will be notified.

Note: Certain conditions will allow the machine to be operated in the limp home mode.

to Table 1 for the status of the alarm of each warning level.

If the monitoring system detects an abnormal operating condition, the operator will be notified.

The action lamp will flash with an amber color to indicate a level 2 warning. The action lamp will flash with a red color to indicate a level 3 warning.

A Level 2 warning indicates that a failure has occurred and that machine operation will be changed.

The action lamp will flash red and the action alarm will sound to indicate a level 3 warning. A level 3 warning requires an immediate safe shutdown.

Information System:

D7 Track-Type Tractors Information Display Operator Menu
D7 Track-Type Tractors Information Display ECM Summary Menu
D7 Track-Type Tractors Information Display Service Test Menu
D7 Track-Type Tractors Information Display Service Menu
D7 Track-Type Tractors Information Display System Information Menu
D7 Track-Type Tractors Information Display Functions Menu
D7 Track-Type Tractors Information Display Machine Settings Menu
D7 Track-Type Tractors Information Display Menu Navigation
D7 Track-Type Tractors Information Display Display Settings
D7 Track-Type Tractors Information Display Performance Pages
D7 Track-Type Tractors Information Display Display Features - Start-Up Procedure
D7 Track-Type Tractors Information Display Diagnostic Operation
D7 Track-Type Tractors Information Display Indication Display Module - Indicator Ribbon and Message Window
D7 Track-Type Tractors Information Display Operator Profile Menu
D7 Track-Type Tractors Information Display General Information
D7 Track-Type Tractors Information Display Service Tools
D7 Track-Type Tractors Information Display Diagnostic Capabilities
D7 Track-Type Tractors Information Display Determining Diagnostic Trouble Codes
D7 Track-Type Tractors Information Display Diagnostic Trouble Codes
D7 Track-Type Tractors Information Display Event Codes
D7 Track-Type Tractors Information Display Network Connectivity - Test
D7 Track-Type Tractors Information Display Software - Test
D7 Track-Type Tractors Information Display Sensor Supply - Test
D7 Track-Type Tractors Information Display Module - Flash Program