D7E Track-Type Tractor Systems Electronic Control (Fan Hydraulic System) Caterpillar


Electronic Control (Fan Hydraulic System)
`
D7E Track-Type Tractor Systems [UENR4065]
COOLING SYSTEM
D7E Track-Type Tractor Systems Electronic Control (Fan Hydraulic System)
1.1. Electronic Control Modules
2.2. Implement ECM
3.2. ECM Pull Up Voltage
4.2. ECM Pull Down Voltage
5.1. Pin Locations
6.1. Inputs
7.2. Sensors
8.3. Hydraulic Oil Temperature Sensor
9.1. Data Link

Electronic Control Modules

Implement ECM



Illustration 1g03307257


Illustration 2g01309473
ECM Connectors and Contacts

The Implement ECM determines actions that are based on input information and memory information. After the Implement ECM receives the input information, the ECM sends a corresponding response to the outputs. The inputs and outputs of the Implement ECM are connected to the machine harness by two 70 contact connectors (J1 and J2). The ECM sends the information to the AVSpare Electronic Technician (Cat ET) on the Cat Data Link.

Note: The ECM is not serviceable. The ECM must be replaced if the ECM is damaged. Replace the ECM if a failure is diagnosed.

ECM Pull Up Voltage

In order to aid in diagnostics of certain types of electrical circuits that are controlled by the ECM, an internal "pull up voltage" is connected to ECM switch and sensor signal input contacts. An above normal voltage is internally connected to the ECM signal input circuit through a resister.

During normal operation, the switch or sensor signal will hold the circuit low or at a certain signal amplitude, however, circuit conditions such as a loss of power to the component, a disconnection, or an open circuit will allow the circuit to be pulled high by the ECM pull up voltage. This condition will result in an above normal voltage condition at the ECM contact. As a result, the ECM will activate an FMI 03 (voltage above normal) diagnostic code for the affected circuit.

The types of ECM input circuits that have pull up voltage present are:

  • Pulse Width Modulated (PWM) sensor input circuits

  • Switch to Ground Input switch input circuits

  • Active analog (voltage) input signal circuits

  • Passive analog (resistance) input signal circuits

ECM Pull Down Voltage

In order to aid in diagnostics of electrical circuits that are controlled by the ECM, an internal "pull down voltage" is connected to ECM switch to battery type input circuits.

During normal operation, the switch contacts that are allowing the connection to a voltage source will hold the circuit high. When circuit conditions such as a loss of power to the switch supply voltage, a disconnection in the switch circuit or an open circuit will allow the circuit to be pulled low by the ECM pull down voltage. This condition will result in a below normal voltage condition at the ECM contact. As a result, the ECM will activate an FMI 04 (voltage below normal) diagnostic code for the affected circuit.

Pin Locations

Table 1
Implement ECM Contact Description J1 Contact Descriptions(1) 
No.(2)  Type  Function 
11  Sensor Power Output  5V Sensor Supply 
13  Battery Return  Battery - 
21  Sensor Power Return  5V Sensor Return 
22  Analog Input  Hydraulic Oil Temp Sender Temperature Sensor 
23  Battery Return  Battery - 
31  Battery Power Input  Battery + 
38  Battery Power Input  Battery + 
39  Battery Power Input  Battery + 
47  Battery Power Input  Battery + 
56  Sensor Power Return  10V Return 
57  Battery Return  Battery - 
69  Sensory Power Output  10V Sensor Supply 
70  Battery Return  Battery - 
(1) Contacts that are not listed are not used.
(2) The connector contacts that are not listed are not used.

Inputs

The machine has several different types of input devices. The ECM receives machine status information from the input devices and determines the correct output action that is needed in order to control machine operations based on memory and software parameters. The machine utilizes the following types of inputs: switch type and sensor type.

Switches provide signals to the switch inputs of the ECM. The possible outputs of a switch are listed: an open signal, a grounded signal and + battery signal.

Sensors provide an electrical signal to the ECM that constantly changes. The sensor input to the ECM can be one of several different types of electrical signals such as: pulse width modulated (PWM) signals, voltage signals and frequency input signals. Each possible input to the ECM is listed in the tables for the 70-pin connectors.

Inputs provide information to the ECM in the form of sensors or switches.

Sensors

Sensors provide information to the ECM about the intent of the operator or changing conditions. The sensor signal changes proportionally to the changing of operator input or changing conditions. The following types of sensor signals are used by the ECM.

Frequency - The sensor produces a signal and the frequency (Hz) varies as the condition changes.

Pulse width modulated - The sensor produces a signal. The duty cycle of the signal varies as the condition changes. The frequency of this signal is constant.

Analog - The ECM measures the voltage that is associated to a specific condition of the control.

Hydraulic Oil Temperature Sensor



Illustration 3g03345886

The hydraulic oil temperature sensor is a passive analog sensor. The resistance of the sensor changes proportionally to temperature changes. The ECM measures the resistance of the sensor and determines the temperature of the hydraulic oil. If the ECM detects that the hydraulic oil has exceeded a preset temperature, the ECM sends a signal to the engine ECM to engage the hydraulic fan.

Data Link

Electronic communication between the Implement ECM, Power Train ECM, Engine ECM, and the other control modules on the machine is conducted over data link circuits. The data link circuits allow the sharing of information with other electronic control modules. The data link circuits are bidirectional. The data link circuit allows the ECM to send information and to receive information.

The electronic communication system consists of multiple CAN datalink systems.

The SAE J1939 CAN Data Link circuit is separated into different groups. "CAN A" is connected to all of the ECMs on the machine, and is used primarily for information and service purposes, such as the AVSpare Electronic Technician (AVS ET). The other data link systems are high speed data links used for machine control purposes.

Information System:

826K Landfill Compactor, 825K Soil Compactor and 824K Wheel Dozer Engine Supplement Engine - Remove and Install
631K and 637K Wheel Tractor-Scraper Systems Parking Brake
631K and 637K Wheel Tractor-Scraper Systems Relief Valve (Apron) - Test and Adjust
966K XE Wheel Loader Machine Systems Counterweight - Remove and Install
D5R2 and D6R2 Track-Type Tractors HVAC, Heating System
D5R2 and D6R2 Track-Type Tractors HVAC, Control System
631K and 637K Wheel Tractor-Scraper Systems Relief Valve (Push-Pull) - Test and Adjust
950M and 962M Wheel Loaders Power Train, Steering, Braking, Hydraulic, and Machine Systems Tilt Cylinder
631K and 637K Wheel Tractor-Scraper Systems Standby Pressure (Implement Pump) - Test and Adjust
631K and 637K Wheel Tractor-Scraper Systems Brake System Air - Purge
3516B Generator Set Engines with Dynamic Gas Blending Injector Trim File - Install
C280 Marine Engines ECM Software - Install
D4, D6K2 and D6K Track-Type Tractor Systems Fan Hydraulic System
D7E Track-Type Tractor Systems Electronic Control (Steering System)
631K and 637K Wheel Tractor-Scraper Systems Accumulator (Cushion-Hitch) - Test and Charge
950M and 962M Wheel Loaders Power Train, Steering, Braking, Hydraulic, and Machine Systems Differential (Locking)
Tube Assemblies for the Low-Pressure Fuel System on Certain C6.6 Machine Engines{1274, 1307, 1408}
Replacement Procedure for the Selective Catalytic Reduction (SCR) Coolant Lines on D9T Track-Type Tractors{108E}
C4.4 Engines Acceleration Is Poor or Throttle Response Is Poor
950 GC Wheel Loader Power Train Transmission Oil Pump - Remove
C3.4B Engines DEF Return Valve - Test
C4.4 Engines Clean Emissions Module Has High Oxygen Level
C4.4 and C7.1 Engines Coolant Temperature Is Low
950 GC Wheel Loader Power Train Transmission Oil Pump - Install