Illustration 1 | g00103589 |
Pressure differential that opens the bypass valve ... 345 ± 21 kPa (50 ± 3 psi)
(1) 7M-1297 Spring
- Length under test force ... 50.8 mm (2.00 inch)
- Test force ... 176.3 ± 14.1 N (39.64 ± 3.16 lb)
- Free length after test ... 75.7 mm (2.98 inch)
- Outside diameter ... 22.35 mm (.880 inch)
- Test force ... 176.3 ± 14.1 N (39.64 ± 3.16 lb)
(2) 133-2198 Spring
- Length under test force ... 54.41 mm (2.142 inch)
- Test force ... 58.18 ± 2.91 N (13.079 ± .654 lb)
- Free length after test ... 68.95 mm (2.715 inch)
- Outside diameter ... 16.00 mm (.630 inch)
- Test force ... 58.18 ± 2.91 N (13.079 ± .654 lb)
(3) Lubricate the seal with the fluid that is being filtered.
(4) Do not use an air wrench to tighten the filter housing. Make sure that the shoulder of the filter housing contacts the bottom of the oil filter base.
(5) 3S-8652 Spring
- Length under test force ... 25.4 mm (1.00 inch)
- Test force ... 153 ± 12 N (34.4 ± 2.8 lb)
- Free length after test ... 96.5 mm (3.80 inch)
- Outside diameter ... 35.1 mm (1.38 inch)
- Test force ... 153 ± 12 N (34.4 ± 2.8 lb)
9X-7781 Pressure Switch (Filter Bypass)
Note: This switch is used on the machines with the following serial number prefixes: 7HR and 1JW.
Illustration 2 | g01064518 |
Pressure differential that opens the bypass valve ... 345 ± 21 kPa (50 ± 3 psi)
(6) Torque for the two flange nuts ... 20 ± 5 N·m (15 ± 4 lb ft)
(7) Torque for the two nuts ... 3.7 ± 0.3 N·m (32.75 ± 2.65 lb in)
(8) Lubricate the four O-rings with a minimal amount of the lubricant that is being sealed.
(9) Lubricate the O-ring with a minimal amount of the lubricant that is being sealed.
(10) 9X-8071 Spring
- Length under test force ... 22.86 mm (.900 inch)
- Test force ... 4.45 ± 0.50 N (1.000 ± .112 lb)
- Free length after test ... 35.6 mm (1.40 inch)
- Outside diameter ... 16.06 mm (.632 inch)
- Test force ... 4.45 ± 0.50 N (1.000 ± .112 lb)
164-7577 Pressure Switch (Filter Bypass)
Note: This switch is used on the machines with the following serial number prefixes: ADZ and AMP.
Illustration 3 | g01064519 |
Pressure differential that opens the bypass valve ... 345 ± 21 kPa (50 ± 3 psi)
(11) Torque for installing the sensor ... 80 ± 10 N·m (60 ± 7 lb ft)
(12) Lubricate the O-ring with a minimal amount of the lubricant that is being sealed.