IT62G Integrated Toolcarrier and 950G and 962G Wheel Loaders Operator Controls - Left Side Console for Electro-Hydraulic Work Tools Caterpillar


Operator Controls - Left Side Console for Electro-Hydraulic Work Tools
`
1.1. Secondary Steering Test Switch (1)
2.1. Bucket Positioner (2)
3.1. Hazard Flasher (3)
4.1. Lift Kickout Set Switch (4)


Illustration 1g00997960

Secondary Steering Test Switch (1)



Illustration 2g00997237

Secondary Steering Test Switch - Push the secondary steering switch in order to determine whether the secondary steering system and the alert indicator are functional. When the secondary steering switch is pushed, the secondary steering motor will run. Alert indicator (1B) will come on and the action alarm will sound. If alert indicator (1B) does not come on or the action alarm does not sound, do not operate the machine.

Alert indicator (1A) indicates a failure of the primary steering. When alert indicator (1B) flashes, the secondary steering system is active. When the alert indicators come on and the action alarm sounds, steer the machine immediately to a convenient location and stop the machine. Stop the engine and investigate the cause of the failure. Do not operate the machine until the cause of the failure has been corrected.

The AVSpare Monitoring System will perform a self test of the secondary steering during engine start-up. Alert indicator (2) will come on for three seconds in order to verify the pressurization of the secondary steering system. The action alarm will sound until the end of the self test or until the engine is started.


NOTICE

Do not use the secondary steering as a limp home mode procedure.

Continuing to operate the machine by using the secondary steering may result in damage to the secondary steering system.


Bucket Positioner (2)

Bucket/Forks Switch - Press the top of switch (2) in order to actuate the bucket positioner.

Hazard Flasher (3)

Hazard Flasher - The hazard flasher is activated by this switch on the left side of the operator compartment. Push the bottom of the switch in order to activate the hazard flasher. Push the top of the switch in order to deactivate the hazard lights.

An indicator light on the front dash panel will flash when the hazard flasher is activated.

Lift Kickout Set Switch (4)

Lift Kickout Position and Lower Kickout Position - To set the lift kickout, raise the bucket to the desired position above the midway point. Then depress the top of the kickout set switch. The boom will return to the programmed position when the raise detent is activated and the boom is below the kickout position.

To set the lower kickout, lower the bucket to the desired position below the midway point. Then depress the top of the kickout set switch. The boom will return to the programmed position when the float detent is activated and the boom is at least a foot above the kickout position.

Note: If the boom is 305 mm (12 inch) or less above the lower kickout position, placing the lift control lever in the float detent will cause the bucket to float and the bucket will hit the ground.

On electro-hydraulic machines, the work tool positioner must be adjusted manually.

Reference: Refer to the “Machine Adjustments” section of the Operation and Maintenance Manual for the correct adjustment procedures.

Information System:

AD30 Underground Articulated Truck Machine Electrical System Coolant Temperature
AD30 Underground Articulated Truck Machine Electrical System Heating and Air Conditioning
AD30 Underground Articulated Truck Machine Electrical System Window Wiper and Washer
AD30 Underground Articulated Truck Machine Electrical System Speedometer/Tachometer
988H Wheel Loader Plate Locations and Film Locations
834H Wheel Dozer and 836H Landfill Compactor Specifications
D6K Track-Type Tractor Sound Information and Vibration Information
Procedure for Tagging Rental Fleet {1000, 6000, 6700, 7000}
AD30 Underground Articulated Truck Equipment Lowering with Engine Stopped
AD30 Underground Articulated Truck Machine Electrical System Parking Brake
AD30 Underground Articulated Truck Machine Electrical System Residual Brake Oil/Stop Light
D6N Track-Type Tractor Power Train Steering Planetary and Brake - Assemble
963C Track-Type Loader Safety Messages
Installation of the 156-7013 Radiator Field Upgrade Kit on the 994 Wheel Loader{1353}
2003/05/19 A New Pressure Switch for the Torque Converter Lockup is Now Used {1435, 3101}
Installation of Double Lip Wiper Seal{7562}
963C Track-Type Loader Additional Messages
966G II and 972G II Wheel Loaders Rated Load
Torque Converter Output Temperature and Hydraulic Tank Temperature Correction for Certain Track Type Tractors{7490}
TH220B, TH330B and TH340B Telehandlers Hydraulic System Electrical Input Components
980G Series II Wheel Loader Specifications
980G Series II Wheel Loader Rated Load
2003/05/12 New Bearing and Bearing Cap Improves Service Life {6062, 7115}
D11R Track-Type Tractor Hydraulic System Return Screen - Clean