NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Cat products. Dispose of all fluids according to local regulations and mandates. |
Illustration 1 | g00667052 |
Front axle |
Illustration 2 | g00667053 |
Rear axle |
The axles are not equipped with sampling valves. Obtaining a sample of the differential and final drive oil will require a vacuum pump or an equivalent. Withdraw the fluid through the filler opening on the right side of each axle.
Reference: Refer to Special Publication, SEBU6250, "AVSpare Machine Fluids Recommendations" for more information about obtaining a fluid sample.