IT62G Series II Integrated Toolcarrier and 950G Series II and 962G Series II Wheel Loaders Lift Kickout Caterpillar


Lift Kickout
`
IT62G Series II Integrated Toolcarrier and 950G Series II and 962G Series II Wheel Loaders [SEBU7459]
HYDRAULIC SYSTEM
KICKOUT & POSITIONER GP
IT62G Series II Integrated Toolcarrier and 950G Series II and 962G Series II Wheel Loaders Lift Kickout
966G II and 972G II Wheel Loaders Work Tool Positioner
1.1. Electrohydraulic Bucket Controls
2.1. Pilot Hydraulic Bucket Controls

Note: You must establish a configuration for the hydraulic system if the machine was not shipped with a bucket. Use ET in order to establish this configuration. Be sure that non-AVSpare work tools will not interfere with the position sensor. Interference may occur when the bucket is fully racked back and the bucket is fully tilted back. Damage to the position sensor may occur.

Electrohydraulic Bucket Controls



Illustration 1g00777389

To set the lift kickout, raise the bucket to the desired position above the midway point. Then depress the top of the kickout set switch. The boom will return to the programmed position when the raise detent is activated and the boom is below the kickout position.

To set the lower kickout, lower the bucket to the desired position below the midway point. Then depress the top of the kickout set switch. The boom will return to the programmed position when the float detent is activated and the boom is at least 305 mm (12 inch) above the kickout position.

Note: If the boom is 305 mm (12 inch) or less above the lower kickout position, placing the lift control lever in the float detent will cause the bucket to float and the bucket may hit the ground.

To set the bucket kickout position, tilt the bucket to the desired digging angle and depress the bottom of the kickout set switch. The bucket will return to the programmed position when the tilt control lever is placed in the tilt back detent and the bucket is dumped beyond the kickout.

Pilot Hydraulic Bucket Controls

Note: On machines with pilot hydraulic bucket controls, the operator must perform one lift cycle in order to energize the electromagnetic detents. This feature prevents movement of the implement at start-up if the lift control has been accidentally moved to the detent.



Illustration 2g00777585

Note: The operator must activate the bucket positioner and lift kickout by pressing the switch (2) that is located on the switch panel. Press the top of the switch in order to activate the bucket positioner and lift kickout. Press the bottom of the switch in order to deactivate the bucket positioner and lift kickout. On machines with pilot hydraulic bucket controls, a bucket/forks switch is used. This switch is used in order to toggle between two different kickout positions when you are changing from a bucket to a fork.

On machines with pilot hydraulic bucket controls, the kickouts and the positioner must be adjusted manually.

Information System:

IT62G Series II Integrated Toolcarrier and 950G Series II and 962G Series II Wheel Loaders Engine Starting
IT62G Integrated Toolcarrier and 950G and 962G Wheel Loaders Plate Locations and Film Locations
IT62G Series II Integrated Toolcarrier and 950G Series II and 962G Series II Wheel Loaders Rated Load
3054E Industrial Engine Fuel Injection Pump - Install
AD30 Underground Articulated Truck Machine Electrical System Main Power Relay
AD30 Underground Articulated Truck Machine Electrical System Circuit Breaker
2003/05/05 New Engine Software Improves the Engine Compression Brake and Throttle Lock Operation {1920, 7620}
3406E and 3456 Generator Set Engines E173 High Exhaust Temperature Warning
Bench Test Procedure for a D9R Track-Type Tractor Transmission with Differential Steering {3030, 3073}
3500B Series II Marine Engines E100 Low Engine Oil Pressure Warning
3500B Series II Marine Engines E040 Low Engine Oil Pressure Shutdown
AD30 Underground Articulated Truck Braking System System Pressure - Release
3500 Industrial Engines Accumulator Pressure - Test
IT62G Series II Integrated Toolcarrier and 950G Series II and 962G Series II Wheel Loaders Cooling System Coolant Sample (Level 1) - Obtain
2003/05/12 New Front Crankshaft Seals and New Rear Crankshaft Seals are Now in Production {1160, 1161}
D5N Track-Type Tractor Monitoring System
IT62G Series II Integrated Toolcarrier and 950G Series II and 962G Series II Wheel Loaders Differential and Final Drive Oil Sample - Obtain
AD30 Underground Articulated Truck Machine Electrical System Head Light/Park Light
2003/05/05 A New Parking Brake Switch is Available {1408, 1435}
AD30 Underground Articulated Truck Machine Electrical System Block Light/Rear Cab Flood Light
AD30 Underground Articulated Truck Machine Electrical System Directional Turn Signal and Hazard Flasher
AD30 Underground Articulated Truck Machine Electrical System Rear Light/Backup Light
C4.4 (Mech) Industrial Engine Glow Plugs - Test
IT62G Integrated Toolcarrier and 950G and 962G Wheel Loaders Seat