------ WARNING! ------

Personal injury or death can result from a brake malfunction. Do not operate the machine if the brake was applied due to a malfunction of the oil system or the brake.

Correct any problem before attempting to operate the machine.

----------------------

Note: Certain AVSpare machines may be equipped with an optional transmission oil pressure sensor for brake application. The sensor turns on the transmission oil pressure indicator if the transmission oil pressure is low and engages the parking brake if the pressure further decreases (for example, if the engine stalled). If your machine is equipped with the optional transmission oil pressure sensor for brake application, the brake application function needs to be overridden using the 4C-8195 Control Service Tool to enable the brake release function to operate.


NOTICE

Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.

Refer to Special Publication, NENG2500, "AVSpare Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on AVSpare products.

Dispose of all fluids according to local regulations and mandates.


Note: Perform Steps 7 through 9 of the following procedure only to machines fitted with the optional transmission oil pressure sensor.




    Illustration 1g00943687

    1DE3048 Portable Hydraulic Pump

  1. Connect plug (1) of the 212-6102 Portable Hydraulic Pump to the machine's 24 volt DC power supply.

    Note: The machine batteries must be fully charged for the operation of the portable hydraulic pump. If battery charge is low, connect to an external 24 volt DC power supply.

  1. Depress the service brake pedal at least 80 times to release the oil pressure from the brake hydraulic system.

  1. Press and hold the breaker relief valve to release any pressure in the hydraulic tank.



    Illustration 2g00993367



    Illustration 3g00993368

  1. Remove the caps from quick connect couplers (2) and (3) . Connect the hydraulic hoses from the portable hydraulic pump to quick connect couplers (2) and (3) .

  1. Turn the battery disconnect switch to the ON position.

  1. Turn the engine start switch to the ON position.

  1. Connect a 4C-8195 Control Service Tool and a 314-1019 Service Tool Adapter to the service tool port.

    ReferenceFor information on using the 4C-8195 Control Service Tool , refer to the Service Manual, "AVSpare Monitoring System" for the machine that is being serviced.




    Illustration 4g00993369

  1. Use the control service tool to access Mode 7.7 (Transmission Pressure Override) on the AVSpare Monitoring System display window (7) . The default display window reading is "PO-OFF".

  1. Operate the clear switch on the control service tool to change the display window reading to "PO-ON".

    Note: Leave the AVSpare Monitoring System in Mode 7.7 until the procedure has been completed. Changing to another mode will cause the AVSpare Monitoring System to revert to the default setting and the parking brake will not disengage.




    Illustration 5g00943691

  1. Position switch (8) (from the portable hydraulic pump) inside the operator station.

  1. Press and hold switch (8) in the ON position to activate the portable hydraulic pump. Brake accumulator oil pressure indicator (4) will go out when the braking system has full oil pressure.

    Note: Operation of the switch should only take place from inside the operator station. Observe brake indicators and gauges (if equipped) while operating the portable hydraulic pump.

  1. When the braking system has full oil pressure, move parking brake control (6) to the OFF position to disengage the parking brake. Hold switch (8) in the ON position until parking brake indicator (5) on the AVSpare Monitoring System panel goes out. The parking brake is now disengaged.

    Note: The service brakes can be used to stop the machine when the machine has brake oil pressure. Use the service brakes to control the machine when the machine is being towed.

    Note: Using the service brakes will cause the braking system oil pressure to decrease. If brake accumulator oil pressure indicator (4) comes on, operate the portable hydraulic pump to increase the braking system pressure. Ensure that the braking system pressure is maintained for the duration of the towing.


    NOTICE

    Operating the portable hydraulic pump for extended periods of time may cause overheating and possible damage of the electric motor. If overheating is observed, stop operating the portable hydraulic pump and allow it time to cool before towing is continued.


    Note: For the removal of the portable hydraulic pump from the machine, refer to Steps 13 through 16.

    Note: Turning the engine start switch to the OFF position will change the AVSpare Monitoring System Mode 7.7 to the default setting.

  1. Turn the engine start switch to the OFF position.

  1. Repeat Steps 2 through 3.

  1. Disconnect and remove the portable hydraulic pump from the machine.

  1. Install the caps on the quick connect couplers.

Information System:

AD30 Underground Articulated Truck Braking System Parking Brake (Automatic Function)
AD30 Underground Articulated Truck Circuit Breakers - Reset
924G and 924GZ Wheel Loaders Machine Systems Gear Motor (Hydraulic Fan) - Remove
Supplement for the 973C Track-Type Loader With the Steel Mill Arrangement{7000}
Installation of High Intensity Discharge Lights{1434}
C-12 Marine Engines Fuel Temperature Sensor - Remove and Install
TH350B, TH355B, TH360B and TH460B Telehandlers Circuit Breakers - Test
Bench Test Procedure for a 950H, 962H, 966G, 966G Series 2, 966H, 972G, 972G Series 2, and 972H Wheel Loader Transmission and a R1600H Load Haul Dump {3030, 3066, 3073, 3101}
990 Series II Wheel Loader Machine Systems Bucket - Remove
AD30 Underground Articulated Truck Reference Material
AD30 Underground Articulated Truck Hydraulic Tank Screen - Clean
IT28G Integrated Toolcarrier and 924G, 924GZ and 928G Wheel Loaders Engine Supplement Hydraulic and Transmission Oil Cooler - Install
924G and 924GZ Wheel Loaders Machine Systems Gear Motor (Hydraulic Fan) - Install
963C Track-Type Loader Fire Prevention and Explosion Prevention
IT28G Integrated Toolcarrier and 924G, 924GZ and 928G Wheel Loaders Engine Supplement Engine - Remove
3044C Industrial Engine and Engines for Caterpillar Built Machines Fuel Injection Nozzles
990 Series II Wheel Loader Machine Systems Bucket - Install
2003/06/09 New Software Released for Machine Security System (MSS) {7620}
2003/04/21 A Check Valve Is Used to Eliminate the Loss of Oil When the Hydraulic Filter Is Replaced {5051, 5067}
963C Track-Type Loader Power Train Calibration Procedures
TH62, TH63, TH82 and TH83 Telehandlers Specifications
C4.4 Industrial Engine Engine Oil Level - Check
IT28G Integrated Toolcarrier and 924G, 924GZ and 928G Wheel Loaders Engine Supplement Engine - Install
3054E Industrial Engine Fuel Injection Pump - Remove