Auxiliary Control for Attachments
![]() | |
Illustration 1 | g00482544 |
Move the diverter valve lever to the auxiliary position in order to divert flow to the attachment.
![]() | |
Illustration 2 | g00447755 |
Move the lever to position (3) in order to pressurize the left supply line.
Move the lever to position (1) in order to pressurize the right supply line.
Move the lever to position (2) in order to return the lever to the HOLD position.
Attachment Coupler Control
![]() |
Improper attachment of attachments could result in injury or death. Do not operate this machine until you have positive indication that the coupler pins are fully engaged. Check for engagement by: 1. Push the tilt control to tilt the attachment down. 2. Put down pressure on the attachment. 3. Back the machine up and make sure there is not movement between the attachment and the coupler. |
![]() |
![]() | |
Illustration 3 | g00482448 |
Move the diverter valve lever to the coupler position in order to provide flow to the coupler.
![]() | |
Illustration 4 | g00447755 |
Disengage (1) - Move the lever to position (1) in order to disengage the coupler pins. Release the lever in order to return the lever to the HOLD position.
Hold (2) - Release the lever. The coupler pins will remain in the engaged position or in the disengaged position.
Engage (3) - Move the lever to position (3) in order to engage the coupler pins. Release the lever in order to return the lever to the HOLD position.
Note: Make sure that the coupler pins are fully engaged into the attachment before you operate the attachment. Refer to Operation and Maintenance Manual, "Attachment Coupler Operation" for more detailed instructions.
Specific instructions for the operation of the attachment are not provided since the function of the control lever is dependent upon the installation of an Auxiliary Equipment Manufacturer's attachment.