Illustration 1 | g00100777 |
The ejector control (lever) is located at the right of the operator's seat.
![]() | Ejector Return Detent (1) - Push the lever all the way to the right and release the lever. The lever will remain in the detent position and the ejector will move back completely. When the ejector has moved back completely, the lever will be released and the lever will return to the HOLD position. |
Ejector RETURN (2) - Push the lever partially to the right in order to move back the ejector. When you release the lever, the ejector will remain in the position that is selected and the lever will return to the HOLD position.
Ejector HOLD (3) - The lever will return to the HOLD position when the lever is released from the RETURN position or from the FORWARD position. The ejector will remain in the position that is selected.
Ejector FORWARD (4) - Pull the lever toward the operator in order to move the ejector forward. When you release the lever, the ejector will remain in the position that is selected and the lever will return to the HOLD position.
NOTICE |
---|
Do not move the ejector forward with the bowl loaded and the apron closed. Apron damage can result if the ejector is moved forward with the apron closed. The ejector will not operate when the apron control is in the apron FLOAT position. |