When the words "use again" are in the description, the specification given can be used to determine if a part can be used again. If the part is equal to or within the specification given, use the part again.
When the word "permissible" is in the description, the specification given is the "maximum or minimum" tolerance permitted before adjustment, repair and/or new parts are needed.
A comparison can be made between the measurements of a worn part and the specifications for a new part to find the amount of wear. A part that is worn can be safe to use if an estimate of the remainder of its service life is good. If a short service life is expected, replace the part.
![]() |
Disconnect batteries before performance of all service work with the exception of performing voltage testing. |
![]() |
![]() |
At operating temperature, the hydraulic oil tank is hot and under pressure. Hot oil can cause burns. Remove the breather filter cap only when the engine is stopped and the breather filter cap is cool enough to touch. Slowly loosen the breather cap to release any pressure in the hydraulic tank. Be cautious of hot oil when any lines are disconnected in the hydraulic system. |
![]() |
Hydraulic Coupler
Hydraulic Quick Coupler
Hydraulic Quick Coupler